THIS IS MY SELECT

Diesel Generator Sets

D500 GC (60 Hz) Generator Set

Maximum Rating

500 ekW

Minimum Rating

500 ekW

Emissions/Fuel Strategy

EPA Stationary Emergency

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    Cat® C15 In-line 6, 4-cycle diesel

    Bore

    5.4 in

    Stroke

    6.8 in

    Displacement

    928 in³

    Compression Ratio

    16.1:1

    Aspiration

    Turbocharged Air-to-Air Aftercooled

    Fuel System

    MEUI

    Governor Type

    ADEM™A4

    Generator Set Dimensions

    Length - Maximum

    189.6 in

    Width - Maximum

    64.2 in

    Height - Minimum

    2,034 in

    Height - Maximum

    101.7 in

    Dry Weight - Genset (minimum)

    8,280.6 lb

    Dry Weight - Genset (maximum)

    10,346.3 lb

    Generator Set Specifications

    Maximum Rating

    500 ekW

    Minimum Rating

    500 ekW

    Emissions/Fuel Strategy

    EPA Stationary Emergency

    Voltage

    480 to 600 Volts

    Frequency

    60 Hz

    Speed

    1800 RPM

    Duty Cycle

    Standby

    • Air Inlet System
      • Air cleaner - Non-Canister, Disposable
      • Turbocharger
      • Aftercooler core
    • Control Panel
      • GCCP 1.2
    • Cooling System
      • Blower fan and fan drive with guards
      • Jacket water pump, gear driven, centrifugal
      • Radiator sight gauge
      • Coolant drain valve.
      • Thermostats and housing.
      • Radiator, Package mounted.
    • Exhaust System
      • Exhaust manifold; dry
    • Fuel System
      • Engine fuel transfer pump
      • Primary fuel filter w/integral water separator and secondary filter, spin on
      • Integral Tank Base, 24 Hrs, UL142
      • Fuel cooler
      • Fuel priming pump
    • Generator Set
      • All protective devices and control functions simulated and checked
      • Factory tested to design specifications at full load conditions
      • Complete system designed & built at ISO 9001:2000 certified facilities
    • Generators and Generator Attachments
      • Easy access to AVR and terminals
      • Standard winding protection for non-harsh environments with relative humidity ? 95%
      • IP23 protection
      • 6 leads
      • Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)
      • Terminal Box, IP22 RHS Facing, Bottom Cable Entry
      • Voltage regulator (single phase sensing)
      • Insulation, Class H
    • Governing System
      • Cat Electronic Governor (ADEM A4)
    • Lube System
      • Shallow oil pan.
      • Oil filter, spin on.
      • Oil drain with valve.
      • Lubricating Oil, CK-4 (10W-30)
      • Oil cooler
      • Oil filler and dipstick.
      • Fumes disposal to front of radiator.
    • Mounting System
      • Captive linear vibration isolators between base and engine-generator
      • Includes lifting provisions and termination points for coolant and lube oil drain lines
    • Protection
      • Safety Shutoff - High water temperature
      • Safety Shutoff - Overspeed
      • Safety Shutoff - Low Oil Pressure
    • Starting/Charging System
      • 24V,45 amp charging alternator.
      • 24-volt electric starting motor.
    • General
      • Lifting Eyes
      • Vibration damper.
      • Parts Book

    • Air Inlet System
      • Air Cleaner (Non-Canister Disposable)
    • Bases, Mounting & Fuel Tanks
      • Audio & Visual Fuel Alarm (@90% Fuel Level)
      • Wide Base - Skid
      • 5 gallon Spill Containment
      • Fuel Tank Fill Pipe & Lockable Cap
      • Overfill Prevention Valve
      • Integral Tank Base, 24 Hrs, UL142
    • Exhaust
      • Industrial, Residential, Critical Mufflers
    • Circuit Breaker
      • Auxiliary Contacts
      • 600A LSI
      • 600A LS/I
      • 1200A LSI
      • 1200A LS/I
      • 400A LSI
      • 800A LSI
      • 800A LS/I
      • 400A LS/I
    • Control System
      • Twist Release, Red Button Emergency Stop
      • Ground Fault Relay
      • 20A GFCI (Ground Fault Circuit Interrupter)
      • Volt Free Contacts
      • Product Link Remote Monitoring hardware
      • Audible Alarm Gp
      • 16 -light NFPA 99/110 Annunciator
      • 100A Load Center
    • Enclosures
      • E-Stop
      • AC & DC Source Lights
      • Sound Attenuated Level 2 Enclosure (White)
    • Exhaust System
      • Manifold & Turbocharger Guards
      • 8" Muffler - 25 dBA Attenuation
      • Flexible Exhaust Connection
    • Generator
      • Anti-condensation heater
      • Oversize and premium generators
      • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
      • Permanent Magnet Generator
      • Space Heater
    • Starting System
      • Jacket Water Heater
      • Battery Charger (UL Certified)
      • Oversize Battery Set, 1400 CCA, 200 amp/hr.
      • Standard Battery Set: 1000 CCA, 90 amp/hr.
    • Power Termination
      • Circuit breakers, UL listed
      • Circuit breakers, IEC compliant
    • General
      • CSA Certification
      • Extended Service Coverage
      • Generator Test Report
      • UL2200 Certification
      • CSA Certification
      • UL 2200 package
    • Lube System
      • Manual sump pump
    • Mounting System
      • Narrow skid base - replaces standard fuel tank base

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN