THIS IS MY SELECT
DE110 GC Generator Set (60 Hz)
Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
Non Regulated
SPECIFICATIONS
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Engine Specifications
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1 in
105 mm
Stroke
5 in
127 mm
Displacement
268.5 in
4.4 l
Compression Ratio
18.23:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical
Generator Set Dimensions
Length - Maximum
108.1 in
2,745 mm
Width - Maximum
39.3 in
999 mm
Height - Maximum
58.1 in
1,476 mm
Dry Weight - Genset (maximum)
2,932 lb
1,330 kg
Generator Set Specifications
Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
- Engine
- C4.4, Inline 4 cylinder, 4 stroke diesel
- Alternator
- A Frame standard alternator
- Fuel Storage
- Single wall 8 hour fuel tank
- Genset Control
- GCCP 1.1
- Governor
- Mechanical governor
- Enclosure
- Cat GC enclosure
- Air, Cooling & Exhaust
- Enclosure silencer
- General
- Engine and alternator pre-paint, Caterpillar yellow
- Certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance 13
- Auxiliary Supply Voltage
- 120V
- Alternator Requirements
- Space heater
- Fuel Storage
- Dual wall 8 hour fuel tank
- Low fuel level shutdown
- Single wall tank with containment
- Low fuel level alarm
- High fuel level alarm
- Genset Control
- Volt free contacts for genset running
- Emergency stop with key
- Battery charger
- Earth fault
- USB to RS485 Communications device
- Panel mounted audible alarm
- Earth leakage
- Volt free contacts for common alarm
- USB to RS485 Communications device
- Coolant heater
- Battery
- Low coolant level shutdown
- Standby Pack (Smart Jacket water heater, Battery charger)
- Circuit breaker
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 3 Pole Circuit breaker 250A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 250A
- Circuit breaker padlock
- 4 Pole Circuit breaker 400A
- Neutral earth link
- Overload via alarm switch on breaker
- Testing & Packaging
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF
Similar Models
WHY CHOOSE EMPIRE
-
Machines built tough and ready to run in rugged applications
-
Trusted advisors to help you find and maximize your equipment
-
Wide inventory of rental equipment that lets you try before you buy
-
Full service and support to ensure performance and longevity