Maximum Rating
200 kVA
Minimum Rating
200 kVA
Emissions/Fuel Strategy
Non Regulated
SPECIFICATIONS
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Engine Specifications
Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
105 mm
Stroke
5.3 in
135 mm
Displacement
427.8 in³
7 l
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical
Generator Set Dimensions
Length - Maximum
130.9 in
3,325 mm
Width - Maximum
44.6 in
1,134 mm
Height - Maximum
65.6 in
1,666 mm
Dry Weight - Genset (maximum)
4,257 lb
1,931 kg
Generator Set Specifications
Maximum Rating
200 kVA
Minimum Rating
200 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby
- Engine
- C7.1, Inline 6 cylinder, 4 stroke diesel
- Control Panels
- GCCP 1.1
- Enclosure
- Cat GC enclosure
- Fuel Storage
- Single wall 8 hour fuel tank
- Alternator
- A Frame standard alternator
- Governor
- Mechanical governor
- Air, Cooling & Exhaust
- Enclosure silencer
- General
- Engine and alternator pre-paint, Caterpillar yellow
- Auxiliary Supply Voltage
- 120V
- Certification
- Certificate of Conformance
- Australia, CIS, Gulf Certification
- Alternator Requirements
- Space heater
- Fuel Storage
- Dual wall 8 hour fuel tank
- Single wall tank with containment
- Low fuel level alarm
- Low fuel level shutdown
- High fuel level alarm
- Genset Control
- Panel mounted audible alarm
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Battery charger
- Earth leakage
- USB to RS485 Communications device
- Emergency stop with key
- Earth fault
- Coolant heater
- Low coolant level shutdown
- Battery
- Standby Pack (Smart Jacket water heater, Battery charger)
- Circuit breaker
- 4 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 250A
- 3 Pole Circuit breaker 630A
- 3 Pole Circuit breaker 200A
- 3 Pole Circuit breaker 250A
- 4 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 630A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 400A
- Testing & Packaging
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF