DE550S GC (60 Hz) Generator Set

Maximum Rating

550 ekW

Minimum Rating

550 ekW

Emissions/Fuel Strategy

Non Regulated

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C15 In-line 6, 4-cycle diesel

    Bore

    5.4 in

    Stroke

    6.8 in

    Displacement

    928 in³

    Compression Ratio

    16.1:1

    Aspiration

    Turbocharged Air-to-Air Aftercooled

    Fuel System

    EUI

    Governor Type

    Adem™A4

    Generator Set Dimensions

    Length - Maximum

    131 in

    Width - Maximum

    60.6 in

    Height - Maximum

    86.1 in

    Dry Weight - Genset (maximum)

    8,364 lb

    Generator Set Specifications

    Maximum Rating

    550 ekW

    Minimum Rating

    550 ekW

    Emissions/Fuel Strategy

    Non Regulated

    Voltage

    220 to 480 Volts

    Frequency

    60 Hz

    Speed

    1800 RPM

    Duty Cycle

    Standby

    • Engine
      • Cat® C15 Inline 6 cylinder, 4 stroke diesel
    • Air Inlet
      • Air cleaner
    • Control Panels
      • GCCP 1.1
    • Governor
      • Mechanical governor
    • Alternator
      • A Frame standard alternator
    • Control Panel
      • EMCP 4 Genset controller
    • Cooling
      • Package mounted radiator
    • Fuel Storage
      • Single wall 8 hour fuel tank
    • Cooling System
      • Radiator and cooling fan with guards
      • Fan drive, battery charging alternator drive
    • Exhaust
      • Exhaust flange outlet
    • Fuel
      • Fuel priming pump
      • Secondary fuel filters
      • Primary fuel filter with integral water separator
    • Electrical Options
      • 3 Pole Circuit breaker
      • Neutral earth link
      • 24 Volt battery with rack and cables
    • Air inlet system
      • Air cleaner; light duty with disposable element
    • Lube system
      • Lubricating oil
      • Oil drain line with valve
    • Generator
      • Matched to the performance and output characteristics of Cat engines
      • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
      • IP23 Protection
    • Mounting system
      • Captive linear vibration isolators
      • Lifting provision and drag points
    • Power Termination
      • Busbar
    • Generator and Attachments
      • Integrated voltage regulator (IVR)
      • Power center, IP22
      • Optional LC Frame generator - IP23 Protection
      • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
      • Segregated low voltage (AC/DC) wiring panel
    • Mounting
      • Rubber vibration isolators
    • Governing System
      • Cat electronic governor (ADEM A4).
    • Lube System
      • Oil drain valves
      • Oil cooler
    • Mounting System
      • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
    • Starting/Charging
      • 24 volt starting motor
      • Batteries
      • 24 Volt battery with rack and cables
    • General
      • Engine and alternator pre paint, Caterpillar yellow
      • Paint - Caterpillar yellow except rails and radiators gloss black
      • Engine and alternator pre paint, Caterpillar yellow

    • Control panel
      • Speed and Voltage adjust potentiometers
      • PLG 4G/3G/Ethernet
      • Annunciator
      • Emergency E-Stop
    • Exhaust
      • Industrial, residential, critical mufflers
    • Enclosure
      • Cat GC enclosure
    • Generator
      • Oversize and premium generators
      • Anti-condensation heater
      • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Electrical Options
      • 4 Pole Circuit breaker
      • Auxiliary contacts
      • Padlockable circuit breaker
      • Battery charger
      • Wet battery
    • Power Termination
      • Circuit breakers, UL listed
      • Circuit breakers, IEC compliant
    • Alternator
      • Space heater
      • AVR
    • Air inlet system
      • Single stage air filter
      • Dual element air filter
    • Starting/Charging
      • Heavy duty starting system
      • Battery chargers
      • Jacket water heater
      • Oversize batteries
      • Charging alternator
    • Certifications
      • EU Certificate of Conformance (CE)
      • EAC Certification
    • Extended service coverage
      • 3, 4, 5 and 10 Years
    • General
      • The following options are based on regional and product configuration:
      • UL 2200 package
      • Integral & sub-base UL listed dual wall fuel tanks
      • Sound attenuated, weather protective or high ambient weather protective enclosure
      • EU Certificate of Conformance (CE)
      • EEC Declaration of Conformity
      • Single or dual wall integral fuel tanks
      • Single or dual wall sub-base fuel tanks
      • CSA Certification
      • Automatic transfer switches (ATS)
      • Narrow, wide or skid base
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • Enclosures
      • High ambient sound attenuated enclosures
    • Exhaust System
      • Industrial silencer
      • 10 dBA Attenuation silencer
      • 6 and 8 inch elbow kit
      • Flexible exhaust fittings
      • Manifold and turbocharger guards
      • End in/end out mufflers - 10, 25 and 35 dBA attenuation
      • Engine mounted muffler
      • 6 and 8 inch flange GP
    • Fuel System
      • Dual wall 8 hour fuel tank
      • Single wall 8 hour fuel tank with spill containment
      • Low fuel level shutdown
      • Low and high fuel level alarms
      • Fuel transfer system controls
      • Dual wall fuel tank base
      • Manual fuel transfer pump
    • Generator and Attachments
      • Ingress protection
      • CIP A Frame generator
      • Oversize A Frame generator
      • Permanent magnet excitation (PMG) generator
      • Space heaters
      • LC frame CIP generator
      • LC frame generator
      • Oversize LC frame generator
    • Lube System
      • Manual sump pump
    • Mounting System
      • Narrow skid base - replaces standard fuel tank base
    • Special Test / Reports
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8 power factor
    • Starting / Charging System
      • Battery disconnect switch
      • Jacket water heater
      • 5 Amp single Battery charger

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN