Maximum Rating

88 kVA

Minimum Rating

88 kVA

Emissions/Fuel Strategy

Non Regulated

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C4.4, In-line 4, 4-cycle diesel

    Bore

    4.1 in

    Stroke

    in

    Displacement

    268.5 in

    Compression Ratio

    17.25:1

    Aspiration

    Turbocharged

    Fuel System

    Inline

    Governor Type

    Mechanical

    Generator Set Dimensions

    Length - Maximum

    89.6 in

    Width - Maximum

    43.3 in

    Height - Maximum

    57.7 in

    Dry Weight - Genset (maximum)

    1,245 lb

    Generator Set Specifications

    Maximum Rating

    88 kVA

    Minimum Rating

    88 kVA

    Emissions/Fuel Strategy

    Non Regulated

    Voltage

    380 to 415 Volts

    Frequency

    50 Hz

    Speed

    1500 rpm

    Duty Cycle

    Standby

    • Engine
      • C4.4, Inline 4 cylinder, 4 stroke diesel
    • Fuel Storage
      • Single wall 8 hour fuel tank
    • Governor
      • Mechanical governor
    • Alternator
      • A Frame standard alternator
    • Genset Control
      • GCCP 1.1
    • Enclosure
      • Cat GC enclosure
    • Air, Cooling & Exhaust
      • Enclosure silencer
    • General
      • Engine and alternator pre-paint, Caterpillar yellow

    • Certification
      • Certificate of Conformance
      • Australia, CIS, Gulf Certification
    • Auxiliary Supply Voltage
      • 120V
    • Alternator Requirements
      • Space heater
    • Fuel Storage
      • Dual wall 8 hour fuel tank
      • Single wall tank with containment
      • Low fuel level shutdown
      • High fuel level alarm
      • Low fuel level alarm
    • Genset Control
      • Volt free contacts for genset running
      • Emergency stop with key
      • Earth leakage
      • Volt free contacts for common alarm
      • Battery charger
      • Earth fault
      • Panel mounted audible alarm
      • Coolant heater
      • Standby Pack (Smart Jacket water heater, Battery charger)
      • Battery
      • Low coolant level shutdown
    • Circuit breaker
      • 3 Pole Circuit breaker 160A
      • 3 Pole Circuit breaker 125A
      • 3 Pole Circuit breaker 200A
      • 4 Pole Circuit breaker 125A
      • 3 Pole Circuit breaker 400A
      • 4 Pole Circuit breaker 160A
      • 3 Pole Circuit breaker 250A
      • 4 Pole Circuit breaker 200A
      • 4 Pole Circuit breaker 250A
      • Circuit breaker padlock
      • 4 Pole Circuit breaker 400A
      • Neutral earth link
      • Overload via alarm switch on breaker
    • Testing & Packaging
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8PF